# EU 230 V.

![EU 230 V](https://tr.elvorka.com/assets/optimized/ed4fde160f2f91fd-1048-q92.webp)

Integrated system

# EU 230 V.

An integrated inverter and 51.2 V LFP battery system. Three listed power-and-capacity configurations, with rated AC output of 6.2 or 12 kW.

INVERTER  Included

ENCLOSURE  IP21

NOMINAL ENERGY  10.24 / 16.076 kWh

AC CONFIGURATION  230 V AC / 50 or 60 Hz

[Start your project ↗](https://tr.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Rated AC (kW) |
| --- | --- | --- |
| 6.2K-10/16KWH-EU | 10.24 | 6.2 |
| 6.2K-10/16KWH-EU | 16.076 | 6.2 |
| 12K-16KWH-EU | 16.076 | 12 |

6.2 kW AC configurations: 1 MPPT and max. PV 6.5 kW. 12 kW AC: 2 MPPT and max. PV 2 × 9 kW. Wi-Fi, parallel operation and CT options require confirmation.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 105 |
| 6.2K-10/16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 |
| 12K-16KWH-EU | 552 × 254 × 1210 / L × W × H | 130 |

Communication: USB / RS485 / dry contact
Temperature: Charge 0 to 55 °C; discharge −20 to 55 °C

## Plan for coastal summers, damp rooms and inland winters.

MGM distinguishes coastal, Mediterranean, Marmara, Black Sea and continental conditions. The relevant value for a battery is the actual temperature and exposure in its equipment area, not one temperature assigned to all Türkiye.

Temperature:  Charge 0 to 55 °C; discharge −20 to 55 °C

ENCLOSURE  IP21

01

### Mediterranean / Aegean home · summer heat

Coastal conditions differ from the continental interior. Check whether the proposed room collects afternoon or roof heat.

An EU all-in-one has an IP21 housing and needs cooling and service space. Its listed charge range of 0 to 55 °C does not establish full-power operation at the top limit. For HP Ultra, confirm the selected configuration's temperature limits separately.

What is the hottest observed temperature at the unit?

- Does the room stay enclosed during summer?

- What output derating and ventilation requirements apply to the exact model?

02

### Marmara / Black Sea home · moisture checks

MGM identifies these as distinct climate types. Check local rain exposure and indoor damp instead of assuming an enclosure rating solves the whole site.

TR Pro and HP Ultra list IP66, while EU lists IP21 and other families have IP20 or optional IP54. These are not evidence of flood, condensation or salt-spray suitability. Select a protected equipment space and confirm the model's site requirements.

Can rain, damp or condensation reach the equipment?

- Is coastal salt-air exposure relevant to the location?

- Are service connections protected and the equipment area kept clear?

03

### Interior or eastern location · cold-season charging

MGM describes more continental conditions inland. An unheated room or garage needs a local temperature check even when the occupied home is warm.

TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; the lower discharge figure is not a charging permission. Optional self-heating must be confirmed for the selected model. TA6000's general operating field does not independently establish its battery charging boundary.

Can charging occur when the battery is below 0 °C?

- Which confirmed heating and low-temperature charge protections are provided?

- Can the installation use a dry temperature-controlled equipment room?

Specifications

- EU and TA6000 are integrated battery-plus-inverter systems. TR, HP and TB are battery-only families requiring a compatible external inverter.

- Choose the actual temperature and enclosure configuration. Optional self-heating is not a claim that every family charges below 0 °C.

- Match DC voltage, currents, protocol and the required AC/phase configuration before choosing capacity. More kWh does not automatically increase AC output.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Views and numbering come only from the supplied one-page EU brochure. The source does not provide pinouts, cable sizing, wiring procedures or a complete set of every exterior face. Native side-image resolution is modest. A rendered map improves the original vector labels, not the native photographic detail.

[![Original numbered interface map](https://tr.elvorka.com/assets/product-details/eu-interface-map.png)](https://tr.elvorka.com/assets/product-details/eu-interface-map.png)

Original numbered interface map  Numbered map of the AC, battery, PV and communication connections.

[![AC and battery connection side](https://tr.elvorka.com/assets/product-details/eu-ac-side-full.png)](https://tr.elvorka.com/assets/product-details/eu-ac-side-full.png)

AC and battery connection side  AC and battery connection side with cooling fans and the battery breaker.

[![AC and battery upper detail](https://tr.elvorka.com/assets/product-details/eu-ac-side-upper.png)](https://tr.elvorka.com/assets/product-details/eu-ac-side-upper.png)

AC and battery upper detail  Upper AC connection area, cooling fans and BAT terminals.

[![PV and communication side](https://tr.elvorka.com/assets/product-details/eu-pv-side-full.png)](https://tr.elvorka.com/assets/product-details/eu-pv-side-full.png)

PV and communication side  PV and communication side, including the battery communication ports.

[![PV and communication upper detail](https://tr.elvorka.com/assets/product-details/eu-pv-side-upper.png)](https://tr.elvorka.com/assets/product-details/eu-pv-side-upper.png)

PV and communication upper detail  Ventilation grille above the PV and communication connection area.

### Know your interfaces.

#### Power connections

AC input / output  The AC connection identified by number 1 in the original map.

AC input breaker  Breaker labelled for the AC input.

BAT+ / BAT-  Positive and negative battery terminals, as labelled in the source.

PV input  Input identified for the PV connection.

#### Communication

Parallel communication port  Communication connection labelled for parallel operation; configuration availability must be confirmed separately.

Dry contact control  Control interface labelled as dry contact in the brochure.

RS485 / BMS communication port  The communication connection named RS485/BMS in the original label.

Wi-Fi port  Port labelled Wi-Fi; the source specification lists Wi-Fi as an option requiring confirmation.

USB communication port  Communication interface labelled USB.

Battery communication ports  The source points to the group of three circular openings with label 11. It does not identify these as AC power inputs.

#### Controls & indicators

Battery breaker  Breaker identified for the battery section.

Source: EU 230 V product sheet · PDF page 1

---

https://tr.elvorka.com/en/products/eu-230v/

ELVORKA · eric@elvorka.com