# HP Ultra.

![HP Ultra](https://tr.elvorka.com/assets/optimized/aad85a50fc62c866-1254-q92.webp)

High-voltage battery

# HP Ultra.

A modular aluminium-alloy LFP battery stack. Six specified configurations from 8 to 48 kWh, for integration with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66 / aluminium alloy

NOMINAL ENERGY  8–48 kWh

BATTERY VOLTAGE  Confirm selected configuration

[Start your project ↗](https://tr.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Max. DC (kW) |
| --- | --- | --- |
| HP Ultra-8.0 | 8 | 4 |
| HP Ultra-16.0 | 16 | 8 |
| HP Ultra-24.0 | 24 | 12 |
| HP Ultra-32.0 | 32 | 16 |
| HP Ultra-40.0 | 40 | 20 |
| HP Ultra-48.0 | 48 | 24 |

System voltage and inverter compatibility must be confirmed for the chosen capacity. Floor-standing or wall-mounted installation is listed. Module additions require system review.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| HP Ultra-8.0 | 950 × 315 × 575 / W × D × H | 75 |
| HP Ultra-16.0 | 950 × 315 × 880 / W × D × H | 130 |
| HP Ultra-24.0 | 950 × 315 × 1185 / W × D × H | 185 |
| HP Ultra-32.0 | 950 × 315 × 1490 / W × D × H | 240 |
| HP Ultra-40.0 | 950 × 315 × 1795 / W × D × H | 295 |
| HP Ultra-48.0 | 950 × 315 × 2100 / W × D × H | 350 |

Communication: CAN / RS485 / Wi-Fi / Bluetooth
Temperature: Confirm selected configuration

## Plan for coastal summers, damp rooms and inland winters.

MGM distinguishes coastal, Mediterranean, Marmara, Black Sea and continental conditions. The relevant value for a battery is the actual temperature and exposure in its equipment area, not one temperature assigned to all Türkiye.

Temperature:  Confirm selected configuration

ENCLOSURE  IP66 / aluminium alloy

01

### Mediterranean / Aegean home · summer heat

Coastal conditions differ from the continental interior. Check whether the proposed room collects afternoon or roof heat.

An EU all-in-one has an IP21 housing and needs cooling and service space. Its listed charge range of 0 to 55 °C does not establish full-power operation at the top limit. For HP Ultra, confirm the selected configuration's temperature limits separately.

What is the hottest observed temperature at the unit?

- Does the room stay enclosed during summer?

- What output derating and ventilation requirements apply to the exact model?

02

### Marmara / Black Sea home · moisture checks

MGM identifies these as distinct climate types. Check local rain exposure and indoor damp instead of assuming an enclosure rating solves the whole site.

TR Pro and HP Ultra list IP66, while EU lists IP21 and other families have IP20 or optional IP54. These are not evidence of flood, condensation or salt-spray suitability. Select a protected equipment space and confirm the model's site requirements.

Can rain, damp or condensation reach the equipment?

- Is coastal salt-air exposure relevant to the location?

- Are service connections protected and the equipment area kept clear?

03

### Interior or eastern location · cold-season charging

MGM describes more continental conditions inland. An unheated room or garage needs a local temperature check even when the occupied home is warm.

TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; the lower discharge figure is not a charging permission. Optional self-heating must be confirmed for the selected model. TA6000's general operating field does not independently establish its battery charging boundary.

Can charging occur when the battery is below 0 °C?

- Which confirmed heating and low-temperature charge protections are provided?

- Can the installation use a dry temperature-controlled equipment room?

Specifications

- EU and TA6000 are integrated battery-plus-inverter systems. TR, HP and TB are battery-only families requiring a compatible external inverter.

- Choose the actual temperature and enclosure configuration. Optional self-heating is not a claim that every family charges below 0 °C.

- Match DC voltage, currents, protocol and the required AC/phase configuration before choosing capacity. More kWh does not automatically increase AC output.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

Six specified 8-48kWh configurations only. Original introduction figures show an unlabeled representative stack; no underside, complete installed rear, wiring pinout or activation interface is supplied. DC poles/breaker/heatsinks and communication/parallel/GND belong to different illustrated faces. Small native drawings must not be presented as high-resolution product photography. The broader '8.0-128.0' heading is not a list of additional individually specified models.

[![DC electrical / heatsink face - original callouts](https://tr.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)](https://tr.elvorka.com/assets/product-details/hp-ultra-dc-face-callouts.png)

DC electrical / heatsink face - original callouts  DC-side view showing the switch, battery terminals, DC breaker and heat-dissipation plate.

[![Communication and parallel-interface face - original callouts](https://tr.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)](https://tr.elvorka.com/assets/product-details/hp-ultra-com-face-callouts.png)

Communication and parallel-interface face - original callouts  Communication-side labels for inverter links, backup communication, BMS debugging, parallel COM1/COM2 and GND.

[![Communication-side detail (partial oblique view)](https://tr.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)](https://tr.elvorka.com/assets/product-details/hp-ultra-communication-side-detail.png)

Communication-side detail (partial oblique view)  Oblique detail of the stack's communication-side connector area.

[![Module top / mating surfaces](https://tr.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)](https://tr.elvorka.com/assets/product-details/hp-ultra-module-top-connectors.png)

Module top / mating surfaces  Battery module top and mating surfaces.

### Know your interfaces.

#### Power connections

Positive Pole  Positive terminal identified by the original leader line on the electrical face.

Negative Pole  Negative terminal identified by the original leader line on the electrical face.

#### Communication

Bluetooth/WIFI Antenna  Antenna label on the upper communication-side area.

Backup Com  The brochure labels this connection 'Backup Com' but does not explain its exact role.

INV CAN/RS485 Com  The INV-labelled CAN/RS485 communication connection shown in the original diagram.

Parallel COM1  First parallel-communication label near the lower part of the illustrated interface face.

Parallel COM2  Second parallel-communication label near the lower part of the illustrated interface face.

#### Controls & indicators

Switch  Switch labelled on the DC electrical-side illustration; its detailed switching function is not specified.

DC Breaker  DC breaker on the electrical / heatsink face.

Breathing Light  Light strip called out at the upper front portion in the oblique construction view.

#### Structure & mounting

Heat Dissipation Aluminum Plate  Heat-dissipation aluminum plate called out on the slim electrical-side illustration.

Wall Mounted Bracket  Mounting brackets shown on the vent-side illustration.

PDU  PDU labels the top unit in the component hierarchy; the brochure does not expand the abbreviation.

Module  Repeated battery sections below the top PDU.

Base  Base at the bottom of the illustrated stack.

BMS Debugging Interface  BMS debugging interface identified on the communication-side illustration.

Pressure Relief Valve  Pressure-relief component called out in the communication-side oblique view.

GND  Ground connection labelled GND at the bottom of the interface-side illustration.

Source: Residential ESS brochure · PDF page 5 · printed pages 9-10

---

https://tr.elvorka.com/en/products/hp-ultra/

ELVORKA · eric@elvorka.com