# TB rack.

![TB rack](https://tr.elvorka.com/assets/optimized/2b8fe35077745c40-1584-q92.webp)

Low-voltage battery

# TB rack.

Four specified LFP battery capacities for rack-mounted storage and a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP20

NOMINAL ENERGY  5.12–16.076 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://tr.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Rated DC (kW) |
| --- | --- | --- |
| TB4000X | 5.12 | 5 |
| TB6000X | 10.24 | 10 |
| TB8000X | 14.336 | 10 |
| TB8500X | 16.076 | 10 |

Wi-Fi / Bluetooth is listed for TB6000X, TB8000X and TB8500X, excluding TB4000X. Power ratings are battery-side DC.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TB4000X | 482 × 178 × 420 / W × H × D | 42 |
| TB6000X | 482 × 223 × 550 / W × H × D | 78 |
| TB8000X | 482 × 223 × 710 / W × H × D | 109.5 |
| TB8500X | 482 × 223 × 710 / W × H × D | 112 |

Communication: RS485 / CAN / RS232
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

## Plan for coastal summers, damp rooms and inland winters.

MGM distinguishes coastal, Mediterranean, Marmara, Black Sea and continental conditions. The relevant value for a battery is the actual temperature and exposure in its equipment area, not one temperature assigned to all Türkiye.

Temperature:  Charge 0 to 55 °C; discharge −20 to 60 °C

ENCLOSURE  IP20

01

### Mediterranean / Aegean home · summer heat

Coastal conditions differ from the continental interior. Check whether the proposed room collects afternoon or roof heat.

An EU all-in-one has an IP21 housing and needs cooling and service space. Its listed charge range of 0 to 55 °C does not establish full-power operation at the top limit. For HP Ultra, confirm the selected configuration's temperature limits separately.

What is the hottest observed temperature at the unit?

- Does the room stay enclosed during summer?

- What output derating and ventilation requirements apply to the exact model?

02

### Marmara / Black Sea home · moisture checks

MGM identifies these as distinct climate types. Check local rain exposure and indoor damp instead of assuming an enclosure rating solves the whole site.

TR Pro and HP Ultra list IP66, while EU lists IP21 and other families have IP20 or optional IP54. These are not evidence of flood, condensation or salt-spray suitability. Select a protected equipment space and confirm the model's site requirements.

Can rain, damp or condensation reach the equipment?

- Is coastal salt-air exposure relevant to the location?

- Are service connections protected and the equipment area kept clear?

03

### Interior or eastern location · cold-season charging

MGM describes more continental conditions inland. An unheated room or garage needs a local temperature check even when the occupied home is warm.

TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; the lower discharge figure is not a charging permission. Optional self-heating must be confirmed for the selected model. TA6000's general operating field does not independently establish its battery charging boundary.

Can charging occur when the battery is below 0 °C?

- Which confirmed heating and low-temperature charge protections are provided?

- Can the installation use a dry temperature-controlled equipment room?

Specifications

- EU and TA6000 are integrated battery-plus-inverter systems. TR, HP and TB are battery-only families requiring a compatible external inverter.

- Choose the actual temperature and enclosure configuration. Optional self-heating is not a claim that every family charges below 0 °C.

- Match DC voltage, currents, protocol and the required AC/phase configuration before choosing capacity. More kWh does not automatically increase AC output.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The native front feature illustration and exploded callout illustration have visible layout differences and are not proven to be the same hardware revision. Keep each original view's source identity. The source has no external rear-view photograph. Internal/thermal diagrams must not be described as exterior rear or underside photos.

[![Original front terminal and control strip](https://tr.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)](https://tr.elvorka.com/assets/product-details/tb-rack-front-terminal-strip.png)

Original front terminal and control strip  Front terminal and control strip, with the negative terminal left and positive terminal right.

[![Negative power terminal, front left](https://tr.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)](https://tr.elvorka.com/assets/product-details/tb-rack-negative-terminal.png)

Negative power terminal, front left  Negative terminal and minus mark at the front left.

[![Positive power terminal, front right](https://tr.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)](https://tr.elvorka.com/assets/product-details/tb-rack-positive-terminal.png)

Positive power terminal, front right  Positive terminal and plus mark at the front right.

[![Original communication and control area](https://tr.elvorka.com/assets/product-details/tb-rack-communication-controls.png)](https://tr.elvorka.com/assets/product-details/tb-rack-communication-controls.png)

Original communication and control area  Communication connectors, indicators and power switch on the front control strip.

[![Original cell and BMS construction detail](https://tr.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)](https://tr.elvorka.com/assets/product-details/tb-rack-internal-cells-bms.png)

Original cell and BMS construction detail  Partial internal illustration showing battery cells and the BMS board.

### Know your interfaces.

#### Power connections

Positive power terminal  Power port on the viewer's right in the illustrated front panel, with the original plus mark.

Negative power terminal  Power port on the viewer's left in the illustrated front panel, with the original minus mark.

#### Communication

Dry Connect (source label)  Source names this a communication port labelled 'Dry Connect'. Contact logic, pinout and electrical ratings are not given.

COM0 / COM1 parallel ports  Ports explicitly captioned 'Parallel Port' in this source. Parallel-system limits and wiring are not supplied.

CAN / RS485  Communication port group named CAN/RS485. Appearance alone does not prove Ethernet networking or a compatible inverter protocol.

RS232  Communication port named RS232; exact pinout and adapter requirements are not provided.

#### Controls & indicators

Power switch  Power on/off switch as described in the original caption. Operating sequence is not supplied.

SOC / ALM / RUN indicators  Indicator-light group identified by the source. Individual colour meanings and diagnostic codes are not specified.

Address identification control  Control labelled 'Add'; the caption states automatic address identification. Setup method and address logic are not specified.

#### Structure & mounting

Laser welding  The brochure describes laser welding for the aluminium-plate and cell connection. It is an internal construction feature, not a port.

Steel holder  Internal steel holder identified as fixing the cells; not an external connector.

Plastic steel belt (source wording)  Cell-retaining band described in the source as preventing movement-related impacts; material performance is not independently validated.

Built-in smart BMS  Built-in BMS. The manufacturer lists temperature protection, short-circuit protection and balancing; this extraction does not independently verify those functions.

Portable handle  Steel handle as described in the source. It is not an electrical port.

Source: Residential ESS brochure · PDF page 7 · printed pages 13-14

---

https://tr.elvorka.com/en/products/tb-rack/