# TR Pro.

![TR Pro](https://tr.elvorka.com/assets/optimized/46a9d9acb1b4d427-1560-q92.webp)

Low-voltage battery

# TR Pro.

LFP battery storage in a wall-mounted format, with three specified models and an IP66 enclosure. Pair with a compatible external inverter.

INVERTER  Compatible external inverter required

ENCLOSURE  IP66

NOMINAL ENERGY  10.24 / 16.076 kWh

BATTERY VOLTAGE  51.2 V nominal DC

[Start your project ↗](https://tr.elvorka.com/en/#enquiry)

## Specifications

| Model / configuration | Energy (kWh) | Rated DC (kW) |
| --- | --- | --- |
| TR6000WX-Pro | 10.24 | 10 |
| TR8500WX-Pro | 16.076 | 10 |
| TR8500WX-ProU | 16.076 | 10 |

Self-heating is optional. Power ratings are battery-side DC; actual AC output depends on the selected inverter.

| Model | Dimensions (mm) | Approx. kg |
| --- | --- | --- |
| TR6000WX-Pro | 802 × 620 × 179 / H × L × D | 95 |
| TR8500WX-Pro | 822 × 500 × 250 / H × L × D | 115.5 |
| TR8500WX-ProU | 872 × 500 × 250 / H × L × D | 120 |

Communication: RS485 / RS232 / CAN; Wi-Fi / Bluetooth
Temperature: Charge 0 to 55 °C; discharge −20 to 60 °C

## Plan for coastal summers, damp rooms and inland winters.

MGM distinguishes coastal, Mediterranean, Marmara, Black Sea and continental conditions. The relevant value for a battery is the actual temperature and exposure in its equipment area, not one temperature assigned to all Türkiye.

Temperature:  Charge 0 to 55 °C; discharge −20 to 60 °C

ENCLOSURE  IP66

01

### Mediterranean / Aegean home · summer heat

Coastal conditions differ from the continental interior. Check whether the proposed room collects afternoon or roof heat.

An EU all-in-one has an IP21 housing and needs cooling and service space. Its listed charge range of 0 to 55 °C does not establish full-power operation at the top limit. For HP Ultra, confirm the selected configuration's temperature limits separately.

What is the hottest observed temperature at the unit?

- Does the room stay enclosed during summer?

- What output derating and ventilation requirements apply to the exact model?

02

### Marmara / Black Sea home · moisture checks

MGM identifies these as distinct climate types. Check local rain exposure and indoor damp instead of assuming an enclosure rating solves the whole site.

TR Pro and HP Ultra list IP66, while EU lists IP21 and other families have IP20 or optional IP54. These are not evidence of flood, condensation or salt-spray suitability. Select a protected equipment space and confirm the model's site requirements.

Can rain, damp or condensation reach the equipment?

- Is coastal salt-air exposure relevant to the location?

- Are service connections protected and the equipment area kept clear?

03

### Interior or eastern location · cold-season charging

MGM describes more continental conditions inland. An unheated room or garage needs a local temperature check even when the occupied home is warm.

TR Pro lists charge 0 to 55 °C and discharge −20 to 60 °C; the lower discharge figure is not a charging permission. Optional self-heating must be confirmed for the selected model. TA6000's general operating field does not independently establish its battery charging boundary.

Can charging occur when the battery is below 0 °C?

- Which confirmed heating and low-temperature charge protections are provided?

- Can the installation use a dry temperature-controlled equipment room?

Specifications

- EU and TA6000 are integrated battery-plus-inverter systems. TR, HP and TB are battery-only families requiring a compatible external inverter.

- Choose the actual temperature and enclosure configuration. Optional self-heating is not a claim that every family charges below 0 °C.

- Match DC voltage, currents, protocol and the required AC/phase configuration before choosing capacity. More kWh does not automatically increase AC output.

PRODUCT DETAIL / ORIGINAL LITERATURE

## Every side. Every connection.

The panel illustrates one wheeled representative housing rather than proving every Pro SKU has the same lower body or port placement. Roller is a wheel. Main Circuit Breaker and Battery Switch are separate source labels. Full embedded switch-photo content beyond the printed crop is not promoted to new interface claims.

[![Connection-side terminal labels](https://tr.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)](https://tr.elvorka.com/assets/product-details/tr-pro-terminal-labels.png)

Connection-side terminal labels  Battery terminals, switch, Wi-Fi antenna and communication ports on the cabinet side.

[![Main breaker and folding handle](https://tr.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)](https://tr.elvorka.com/assets/product-details/tr-pro-breaker-side-labels.png)

Main breaker and folding handle  Main circuit breaker and folding handle on the illustrated cabinet side.

[![Original connection-side three-quarter view](https://tr.elvorka.com/assets/product-details/tr-pro-connection-side.png)](https://tr.elvorka.com/assets/product-details/tr-pro-connection-side.png)

Original connection-side three-quarter view  Connection-side view of the cabinet, battery terminals and folding handle.

[![Original narrow side profile](https://tr.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)](https://tr.elvorka.com/assets/product-details/tr-pro-slim-side-profile.png)

Original narrow side profile  Narrow side profile of the illustrated cabinet.

[![Original circuit-switch photograph](https://tr.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)](https://tr.elvorka.com/assets/product-details/tr-pro-switch-original-photo.png)

Original circuit-switch photograph  Circuit-control switch with ON and OFF position markings.

### Know your interfaces.

#### Power connections

Positive battery terminal  Positive DC battery terminal identified on the connection side.

Negative battery terminal  Negative DC battery terminal identified on the connection side.

#### Communication

RS485  RS485 interface named in the source; pinout and compatible device list are not provided.

Wi-Fi antenna  Wi-Fi antenna identified by the original arrow.

CAN  CAN communication interface named in the source; protocol version and pinout are not specified.

RS232  RS232 communication interface named in the source; pinout is not specified.

COM1  Port named COM1; this page does not explicitly define its role or wiring.

COM0  Port named COM0; this page does not explicitly define its role or wiring.

#### Controls & indicators

Breathing light  Front status-light strip identified as a breathing light. Colour meanings and operating logic are not specified.

Main circuit breaker  Main circuit breaker identified by the original arrow. Trip ratings and wiring are not provided here.

Battery switch  Battery switch separately named in the connection-side callout; do not merge this label with Main Circuit Breaker without a model-specific manual.

#### Structure & mounting

Wall-mounted bracket  Mechanical wall-mounting bracket; not an electrical interface.

Rollers  Wheels shown on the representative housing. The label is mechanical and is not a connector or bottom communication port.

Folding handle  Mechanical folding handle; not an electrical connector.

Source: Residential ESS brochure · PDF page 4 · printed pages 7-8

---